China wholesaler Explosion Proof Flameproof Asynchronous Synchronous AC DC Electrical Induction Electric Motor vacuum pump oil

Product Description


Asynchronous Synchronous AC DC Yrkk Induction Electric Motor

ZheJiang ELECTRIC 
Produce Synchronous AC/ DC Yrkk ZZJ Z4 Z  Induction Electric Motor
Power from 10-1000kw 5000kw-50000kw 50mw – 100mw .

Deeply appreciate your enquiry, We are biggest of chinese company 30 years experiences,1000 workers with 10 billion USD turnover in ZheJiang china .Welcome your visiting !!

 

Series Z4 d-c machines are newly developed products of our works. The products are found wide use for prime mover in various, sucb as mill auxilinry in merallurgical induetry, metal cutting machine-tool, paper making, print, textile, printing and dyeing, cement-making, plastic extruding machine, etc.

Outline and mounting dimensions of the motors comply with IEC72 Standard, except for the axial distance between the mounting holes (dimension B).

Performance and technical requirements of the motors can be checked in accordance with IEC34-1 Standard of the International Electro technical Commission, or DIN57530 Norm of the Deutsche Industries-Norm.

The motors are class F insulated, with reliable insulating construction and impregnating process, cnsuring stable dielectric performance and excellent heat dissipation.

The motors possess the features of small size, good performance, light weight, large output, high efficiency and reliability, being able to match the current international advanced level.

The motors can be lastingly operated form fully controlled three-phase bridge without a smoothing reactor. Motors for 160V may be operated on single-phase bridge thyristor. In that case, a smoothing reactor, whose inductance is specified in the relevant technical date, should be inserted in the armature circult to suppres ripple current.

Application: Industrial
Speed: Low Speed
Number of Stator: Three-Phase
Function: Driving, Control
Casing Protection: Closed Type
Number of Poles: 6
Customization:
Available

|

electric motor

What maintenance practices are essential for prolonging the lifespan of an electric motor?

Maintaining electric motors is crucial for prolonging their lifespan and ensuring optimal performance. Proper maintenance practices help prevent failures, minimize downtime, and maximize the efficiency and reliability of electric motors. Here’s a detailed explanation of essential maintenance practices for prolonging the lifespan of an electric motor:

  1. Regular Inspections: Conduct regular visual inspections of the motor to identify any signs of wear, damage, or loose connections. Inspect the motor’s external components, such as the housing, bearings, cooling fans, and cables. Look for any unusual noise, vibration, or overheating during operation, as these can indicate potential issues that require attention.
  2. Lubrication: Proper lubrication is vital for the smooth operation and longevity of electric motors. Follow the manufacturer’s guidelines for lubrication intervals and use the recommended lubricants. Apply lubrication to bearings, shafts, and other moving parts as specified. Over-lubrication or using incompatible lubricants can cause overheating and premature wear, so it’s essential to follow the recommended practices.
  3. Cleaning: Keep the motor clean and free from dirt, dust, and debris that can accumulate over time. Regularly clean the motor’s exterior using a soft brush or compressed air. Ensure that cooling vents and fans are clear of any obstructions to maintain proper airflow and prevent overheating. Cleanliness helps prevent insulation damage and improves heat dissipation.
  4. Alignment and Balance: Misalignment or imbalance in the motor’s shaft and coupling can lead to excessive vibrations and premature wear. Regularly check and correct any misalignment or imbalance issues using precision alignment tools. Proper alignment and balance reduce stress on bearings and extend their lifespan, contributing to the overall longevity of the motor.
  5. Temperature Monitoring: Monitor the motor’s temperature during operation using temperature sensors or thermal imaging techniques. Excessive heat can damage insulation, bearings, and other components. If the motor consistently operates at high temperatures, investigate the cause and take corrective actions, such as improving ventilation, reducing loads, or addressing any cooling system issues.
  6. Electrical Connections: Inspect and tighten electrical connections regularly to ensure secure and reliable connections. Loose or corroded connections can lead to voltage drops, increased resistance, and overheating. Check terminal blocks, wiring, and motor leads for any signs of damage or degradation. Properly torquing electrical connections and addressing any issues promptly helps maintain electrical integrity.
  7. Vibration Analysis: Perform regular vibration analysis to detect any abnormal vibration patterns that could indicate underlying issues. Vibration analysis tools and techniques can help identify unbalanced rotors, misalignment, bearing wear, or other mechanical problems. Addressing vibration issues early can prevent further damage and improve motor performance and longevity.
  8. Periodic Testing and Maintenance: Conduct periodic testing and maintenance based on the manufacturer’s recommendations and industry best practices. This may include insulation resistance testing, winding resistance testing, bearing lubrication checks, and other diagnostic tests. Such tests help identify potential problems before they escalate and allow for timely maintenance and repairs.
  9. Training and Documentation: Ensure that maintenance personnel are properly trained in electric motor maintenance practices. Provide training on inspection techniques, lubrication procedures, alignment methods, and other essential maintenance tasks. Maintain comprehensive documentation of maintenance activities, including inspection reports, maintenance schedules, and repair records.

By implementing these maintenance practices, motor owners can significantly prolong the lifespan of electric motors. Regular inspections, proper lubrication, cleaning, alignment, temperature monitoring, electrical connection maintenance, vibration analysis, periodic testing, and training contribute to the motor’s reliability, efficiency, and overall longevity.

electric motor

What safety precautions should be followed when working with electric motors?

Working with electric motors requires adherence to specific safety precautions to ensure the well-being of individuals and prevent accidents. Electric motors involve electrical hazards that can cause electric shock, burns, or other injuries if proper safety measures are not followed. Here’s a detailed explanation of the safety precautions that should be followed when working with electric motors:

  1. Qualified Personnel: It is important to assign work on electric motors to qualified personnel who have the necessary knowledge, training, and experience in electrical systems and motor operation. Qualified electricians or technicians should handle installation, maintenance, and repairs involving electric motors.
  2. De-Energization and Lockout/Tagout: Before performing any work on electric motors, they should be de-energized, and appropriate lockout/tagout procedures should be followed. This involves isolating the motor from the power source, ensuring that it cannot be energized accidentally. Lockout/tagout procedures help prevent unexpected startup and protect workers from electrical hazards.
  3. Personal Protective Equipment (PPE): When working with electric motors, appropriate personal protective equipment should be worn. This may include insulated gloves, safety glasses, protective clothing, and footwear with electrical insulation. PPE helps protect against potential electrical shocks, burns, and other physical hazards.
  4. Inspection and Maintenance: Regular inspection and maintenance of electric motors are essential to identify potential issues or defects that could compromise safety. This includes checking for loose connections, damaged insulation, worn-out components, or overheating. Any defects or abnormalities should be addressed promptly by qualified personnel.
  5. Proper Grounding: Electric motors should be properly grounded to prevent electrical shock hazards. Grounding ensures that any fault currents are redirected safely to the ground, reducing the risk of electric shock to individuals working on or around the motor.
  6. Avoiding Wet Conditions: Electric motors should not be operated or worked on in wet or damp conditions unless they are specifically designed for such environments. Water or moisture increases the risk of electrical shock. If working in wet conditions is necessary, appropriate safety measures and equipment, such as waterproof PPE, should be used.
  7. Safe Electrical Connections: When connecting or disconnecting electric motors, proper electrical connections should be made. This includes ensuring that power is completely switched off, using appropriate tools and techniques for making connections, and tightening electrical terminals securely. Loose or faulty connections can lead to electrical hazards, overheating, or equipment failure.
  8. Awareness of Capacitors: Some electric motors contain capacitors that store electrical energy even when the motor is de-energized. These capacitors can discharge unexpectedly and cause electric shock. Therefore, it is important to discharge capacitors safely before working on the motor and to be cautious of potential residual energy even after de-energization.
  9. Training and Knowledge: Individuals working with electric motors should receive proper training and have a good understanding of electrical safety practices and procedures. They should be knowledgeable about the potential hazards associated with electric motors and know how to respond to emergencies, such as electrical shocks or fires.
  10. Adherence to Regulations and Standards: Safety precautions should align with relevant regulations, codes, and standards specific to electrical work and motor operation. These may include local electrical codes, occupational safety guidelines, and industry-specific standards. Compliance with these regulations helps ensure a safe working environment.

It is crucial to prioritize safety when working with electric motors. Following these safety precautions, along with any additional guidelines provided by equipment manufacturers or local regulations, helps minimize the risk of electrical accidents, injuries, and property damage. Regular training, awareness, and a safety-focused mindset contribute to a safer working environment when dealing with electric motors.

electric motor

How do electric motors handle variations in load, speed, and torque?

Electric motors are designed to handle variations in load, speed, and torque through various control mechanisms and techniques. Here’s a detailed explanation of how electric motors handle these variations:

  1. Load Variations: Electric motors can handle variations in load by adjusting the amount of torque they produce. When the load on the motor increases, such as when additional resistance or weight is applied, the motor responds by increasing the torque output. This is achieved through the control of the motor’s input current or voltage. For example, in DC motors, increasing the current supplied to the motor can compensate for the increased load, ensuring that the motor can continue to operate at the desired speed.
  2. Speed Variations: Electric motors can handle variations in speed by adjusting the frequency of the power supply or by varying the voltage applied to the motor. In AC motors, the speed is determined by the frequency of the alternating current, so changing the frequency can alter the motor’s speed. In DC motors, the speed can be controlled by adjusting the voltage applied to the motor. This can be achieved using electronic speed controllers (ESCs) or by employing pulse width modulation (PWM) techniques to control the average voltage supplied to the motor.
  3. Torque Variations: Electric motors can handle variations in torque by adjusting the current flowing through the motor windings. The torque produced by a motor is directly proportional to the current flowing through the motor. By increasing or decreasing the current, the motor can adjust its torque output to match the requirements of the load. This can be accomplished through various control methods, such as using motor drives or controllers that regulate the current supplied to the motor based on the desired torque.
  4. Control Systems: Electric motors often incorporate control systems to handle variations in load, speed, and torque more precisely. These control systems can include feedback mechanisms, such as encoders or sensors, which provide information about the motor’s actual speed or position. The feedback signals are compared to the desired speed or position, and the control system adjusts the motor’s input parameters accordingly to maintain the desired performance. This closed-loop control allows electric motors to respond dynamically to changes in load, speed, and torque.

In summary, electric motors handle variations in load, speed, and torque through various control mechanisms. By adjusting the current, voltage, or frequency of the power supply, electric motors can accommodate changes in load and speed requirements. Additionally, control systems with feedback mechanisms enable precise regulation of motor performance, allowing the motor to respond dynamically to variations in load, speed, and torque. These control techniques ensure that electric motors can operate effectively across a range of operating conditions and adapt to the changing demands of the application.

China wholesaler Explosion Proof Flameproof Asynchronous Synchronous AC DC Electrical Induction Electric Motor   vacuum pump oil	China wholesaler Explosion Proof Flameproof Asynchronous Synchronous AC DC Electrical Induction Electric Motor   vacuum pump oil
editor by CX 2023-10-20